Home>Equipment list>Logistics training equipment>Manufacturer of Analog Frequency Conversion Power Supply 100k AC Frequency Conversion Power Supply
    细节展示放大镜特效

      Manufacturer of Analog Frequency Conversion Power Supply 100k AC Frequency Conversion Power Supply

    • No:JL33100A
    • Quantity:

        Recommend

      Model JL33100AT-800V

      Capacity 100 KVA

      input voltageThree-phase three-wire 380V±10%,

      Input frequency 50Hz/60Hz & plusmn; 5Hz

      output voltageThree-phase four-wire+ Ground Wire Voltage: 0.0-800.0V

      output frequencyFixed frequency:50Hz、60Hz、150Hz、300HZ

      Output waveform sinusoidal wave

      Frequency stability < plusmn; 0.1%

      Voltage stability < plusmn; 0.5% FS

      Total harmonic content less than 2% (80% linear load) (THD)

      Voltage deviation of three-phase line < plusmn; 1% FS (load balancing)

      Load effect <1%

      Efficiency (>85%)

      Protection of overload, overcurrent, overheat, short circuit, etc.

      insulation resistanceInput to shell and output:Over 20M (DC1000V); Output over 20M (DC500V)

      Overload capacityInput to shell and output:AC1500V/min, leakage current < 20mA; Output: AC1500V/min, leakage current < 20mA

      Shell Protection Level IP20

      work environmentTemperature:- The humidity of 10 ~40 ~C is 10%~90%(25 ~40 C, no condensation).

      Sea wave height≤2000m

      Shape size(W * H * D) (wide) * 1680 (high) * 800 (deep) for reference only with actual shape as quasi-cabinet color: RAL7035

      Note 1. Input plus filter to prevent interference to the power network of the same source instrument.

      2. Do a good job of internal insulation of power supply, withstand voltage and meet the requirements of insulation.

      3. Power control can choose local control or external control.

      4. Explanation of External Control

      4.1 Frequencies 50HZ, 60HZ, 150HZ, 300HZ can be controlled by external contacts.

      4.2 Voltage 0-800V can be adjusted by DC0-10V

      4.3 If the power supply fails, lead to contact indication

      4.4 Control signals are directly drawn into the chassis and all definitions are defined.

      5. Input open, output contactor control, with status display

      6. Installation of cabinet with locking casters