    Computer room guard(AD-800) Computer roomEnvironmental Monitoring and Alarm System

    Computer room guardAD-800 Short messagenewspaperPolice controlsystemApparatus, yesbookCompany pushOutSection 1WorkPowerfulEmbeddedEntry mode GSM Long-rangenewspaperPolice chiefmachineHe specializes in needsnothingMan on dutyandRemote ControlsystemRequiredprisonControl siteandset upmeterAdoption of industrylevelOf GSM collectHair moduleandHigh Performance 32 Bit ProcessorEmbedded solidtimeoperating system, withYes 8 roadopenClose Input8 Road relaydriveDynamic output4 road 10 accuracy AD MiningSample input interface and one RS232 numberData InterfacestillAccording touseHousehold demandpluspretendbeeSound deviceBatteryandOn board temperaturedegreeSensor chipRealizablefarCheng AlarmRemote ControlFar awayRange measurementetc.functionwideextensiveBe applied tomachineroomnewspaperpoliceBase station monitoringWorkIndustry AutomationturncontrolringEnvironmentMonitorWater supply and other fields.By selecting the corresponding sensor (transducer) devices, it can automatically control the power supply, temperature, humidity, water immersion, smoke sense and machine room equipment.(Output with dry contacts,asUPSPrecision air conditioning)To achieve real-time monitoring, telephone. Short message alarm, to achieve the safety of small and medium-sized computer room without duty.

    I. Brief Introduction of Functions

    High IntegrationOfEmbeddedworkTrade grade CPU And high performance GSM leadQing DynastySupportive wordssoundSMStradeAffairs

    Stable performanceBuilt-in doubleheavyWatchdog

    Provide based on GSM or GPRS Datapasstransport

    Support8Road switchamountand4Circuit levelletterNumber inputnewspaperPolice TriggerInside the alarmRongcanfromUser Definition

    Support8Circuit relayimplementDrive Output

    Support AD sampling

    Rich newspaperspoliceParameter Configuration

    Support for remoteshortCredit controltransportOutgoing and outgoingtooShort Message CheckingInquiryEquipment status

    Support linkagetransportOut

    Wide Voltage(6-30V) Inputlow power consumptionset upmeter

    1、 Municipal Electricity Monitoring: Municipal Electricity Blackout/Resume alarm.

    2、 Monitoring of voltage and current value of municipal electricity.

    3、 Temperature, humidity, smoke, immersion and other environmental parameters alarm.

    4、 Output with dry contactsUPSPrecision air conditioning monitoring alarm.

    5、 Settable10Administrator number.

    6、 Authorized administrators can receive alarm messages,Query the status of each monitoring quantity.

    7、 Setup operation is accomplished by short message interaction or setting software. (Market products generally cannot be owned at the same time)

    8、 Simple installation, users only need to provide a normal text messaging.GSMMobile card is OK.

    9、 It can alarm, send short messages and call at the same time. (Unique function)

    10、 The system has short message distribution defense/Evacuation function. (Unique function)

    11、 There is an alarm linkage output port, (unique function)

    12、 OptionalSupport siteprisonListen and shout (optional)

    13、 Built-in temperaturenewspaperAlarm Sensingimplement(Optional)

    14、 External power supplypoolAnd mentionforOutage telegrampolice(Optional)

    15、 The short message remote control circuit can be switched on and off, and the function of remote opening fan by short message can be realized. (Notes should be made when selecting and purchasing)

    1.2system description

    1.2.1 Monitoring the environmental parameters and intelligent equipment in the computer room:

    The system is equipped.4The analog signal input port,8The input port of the circuit switch signal can monitor the environmental parameters such as the electricity condition, current, voltage, temperature, humidity, water leakage, smoke, infrared, etc. The output of the signal with dry contacts can be monitored.UPSIntelligent equipment such as precision air conditioning.8The output port of circuit switching signal can control the equipment including access control, fan and other machine rooms without any influence on the original system.

    1.2.2 Multi-mode alarm:

    Short Message Alarm: System Support10An administrator, once an alarm occurs, the system automatically sends alarm information to the set administrators.

    Arbitrarily set alarm upper and lower limits, exceed the limits of alarm. Delay alarm time and return difference can be set to avoid critical state and frequent alarm.

    When the alarm is cancelled, the system automatically sends a message to the administrator to return to normal.

    Telephone alarm: Once an alarm occurs, the system first sends a short message to the administrator's mobile phone, and then dials the administrator's mobile phone to avoid missing the alarm information.

    Acousto-optic alarm on the spot: the system provides the scene110 DBaudible and visual alarm,Remind on-site attendants (sound and light alarms should be selected).

    1.2.3 Remote Short Message Query

    All monitoring information queries: send "queries" to the system, and the system automatically replies to the values or states of all monitored parameters.

    Specified parameter query: Send "Query: Name" to query the specified monitoring parameters, and the system automatically returns its value and status.

    When neededUsersopenKai DailyshortLetter ReportWorkGuaranteeset uppreparejustFrequent operation

    1.2.4 Long-range evacuation and deployment of Defense

    Administrators can remotely withdraw or deploy the monitoring system through short messages.

    Withdrawal status: the system continues to monitor the environmental parameters. When an alarm occurs, the host panel indicator lights up, showing the alarm port, but does not send short messages, do not dial the phone, and the sound and light alarm does not act.

    1.2.5 Remote Control

    Open or close the system by sending short messages or login by software8Port, remote control emergency equipment to open and close.

    1.2.6 security

    Only administrators can configure the system. Cell phone numbers of other peopleCan't configure the system

    1.3system composition

    AD-800E-type environmental monitoring and alarm system is the most simple and practical environmental monitoring system for small and medium-sized computer rooms. Users only need to provide a mobile phone card. The system runs independently without affecting or altering the hardware and software resources of the client's existing computer room.