Phosphorus-containing agent alarm

  • No:FDB03
  • Quantity:

      Recommend

    FDB03 phosphorus-containing agent alarm is class I - portable agent alarm, is a Type C - detection of neurotoxic agent, its alarm sensitivity and response time of the product of P-class - allowable level.
    1.2 Uses:
    FDB03 phosphorus-containing agent alarm is for the synthetic army central (sub) team in the field conditions of the use of portable instruments, mainly used to monitor the enemy after the use of phosphorus-containing agent struck the air poisoning, when the air poisoning to a certain extent, will sound and light the way to issue an alarm message.
    1.3 Key technical performance
    1.3.1 Use environment: can be in an environment of -20 to C , 40 degrees C, relative humidity 95% plusmn;
    1.3.2 Sensitivity
    Normal temperature: Sarin concentration of 1.5mg/m 3 within 5 seconds alarm. Alarm within 5 seconds of VX concentration of 3mg/m3. Low temperature, high temperature, wet heat: sarin concentration of 1.5mg/m3 within 5 seconds alarm.
    Alarm within 10 seconds of VX concentration of 4mg/m3.
    3.3.3 Air flow: Sample air flow is 500 to 900 ml/min.
    1.3.4 Work stability: the instrument in the prescribed environmental conditions, after the start-up continuous operation of 2 hours, no downtime and false positives.
    1.3.5 Anti-drying: The instrument does not misreport low concentrations of smoke, automobile engine exhaust and smoke screen under field conditions. Grass smoke on the instrument has dry, should avoid.
    1.3.6 Power and operating hours: The instrument is powered by a lithium battery pack that can be recharged over and over. After the battery pack is fully charged, it can be used continuously for the instrument for more than 6 hours under normal temperature conditions, and for the instrument to be used continuously for more than 4 hours under low temperature, high temperature and wet and hot conditions.
    1.3.7 Sealability: with a rubber seal cap will be air, exhaust mouth, charging socket, acoustics and other parts of the cover, can prevent rain. When immersed in water, other specific waterproofing measures should be taken.
    1.3.8 Form factor: 134mm x 93mm x 43mm (excluding protruding parts).
    1.3.9 Weight: .900g.
    1.3.10 Composition of the toxic alarm
    The toxic agent alarm is mainly used by the host,
    Charger, holster and other parts.