细节展示放大镜特效

Phosphorus poison alarm

  • No:FHBX03
  • Quantity:

    FHBX03 phosphorus-containing poison alarm is a type I portable poison alarm, which belongs to type C and detects nerve poisons. The product of alarm sensitivity and response time is grade P-permissible.
    1.2 Purpose:
    FHBX03 phosphorus-containing poison alarm is a portable instrument used by the central part of the synthetic army under field conditions. It is mainly used to monitor the air poisoning caused by the attack of the enemy using phosphorus-containing poison. When the air poisoning reaches a certain level, it will send out alarm information by sound and light.

    1.3 Main Technical Performance
    1.3.1 Use environment: can work normally in the environment of - 20 + 40 C, relative humidity 95% & plusmn; 5% (+30).
    1.3.2 Sensitivity

    Normal temperature: alarm within 5 seconds when the concentration of sarin is less than 1.5 mg/m3. The alarm should be given within 5 seconds when VX concentration is less than 3 mg/m3. Low temperature, high temperature, humidity and heat: alarm within 5 seconds when the concentration of sarin is less than 1.5 mg/m3.
    The alarm should be given within 10 seconds when VX concentration is less than 4 mg/m3.
    3.3.3 Gas flow rate: Sample gas flow rate is 500-900ml/min.
    1.3.4 Operating stability: The instrument runs continuously for 2 hours after starting up under the prescribed environmental conditions, and there is no outage or false alarm.
    1.3.5 Drying resistance: The instrument does not misreport low concentration smoke, automobile engine exhaust and soot smoke under field conditions. Tobacco smoke should be avoided when it dries up the instrument.

    1.3.6 Power supply and working time: The instrument is powered by a rechargeable lithium battery pack. When the battery pack is fully charged, it can be used continuously for more than 6 hours at room temperature and for more than 4 hours at low temperature, high temperature and humidity.

    1.3.7 Sealability: The rubber seal cap is used to cover the air intake, exhaust nozzle, charging socket, acoustic device and other parts to prevent rain. Other specific waterproofing measures should be taken when they are immersed in water.
    1.3.8 Size: 134?* 93?* 43? (excluding protruding parts).
    1.3.9 weight: <900g.
    1.3.10 The composition of poison alarm is mainly composed of host, charger, leather cover and so on. FHBX03FHBX03