Sulphur hexafluoride leak detector
Characteristics
Intelligent EC sensor, using intrinsic safety technology, can support multi-gas, multi-range detection, and can be customized according to user needs, no tools for sensor interchange, offline calibration and zero self-calibration
Intelligent temperature and zero-point compensation algorithm, so that the instrument has better performance with good selectivity, avoiding interference from other gases to the detected gas
A variety of signal outputs, which can be easily accessed to industrial control systems such as PLC/DCS, and can also be used as a stand-alone control
Oversized dot matrix LCD display, support for Chinese and English interface
No open cover, electrochemical remote control operation, single person maintenance
Local alarm indication, all-in-one sound and light alarm (optional)
The instrument has overrange and antipolar protection to avoid the danger caused by human improper operation
Rich electrical interface for users to choose from
By ATSF6, UL, CSA and other certification, with international high-end quality
Product characteristics of sulfur hexafluoride gas leakage alarm device:
Imported electrochemical sensors have good anti-jamming properties and have a life of 8 years.
'Using advanced microprocessing technology, the response speed is fast, the measurement accuracy is high, the stability and repeatability are good.
The detection site has the function of on-site sound and light alarm, the gas concentration exceeds the standard instant alarm, is the safety of the operation of dangerous places.
4 field with backlit large-screen LCD display, visual display of gas concentration, type, unit, working status, etc.
5 independent gas chamber, replacement sensor does not need on-site calibration, sensor key parameters automatically recognized.
6 Full-scale range temperature digital automatic tracking compensation to ensure measurement accuracy.
Sulphur hexafluoride gas leakage alarm deviceTechnologyParameters:
Detection of gases: sulphur hexafluoride gas emissions from the air
Detection range: 0-100PPM, 0-500PPM, 0-2000PPM
Difference rate: 0.01PPM (0-100PPM, 0-500PPM) 0.1PPM (0-2000PPM)
Working mode: fixed continuous operation, diffusion, pipe, circulation, pump suction optional.
Detection error: 1% (F.S)
Response time: s 10S
Output signal: current signal output 4-20MA
Alarm mode: 2 passive node signal output, alarm point can be set.
Working environment: -20 C to 50 degrees C (special requirements: (-40 C to 70 degrees C)
Relative humidity: s 90%RH
Operating voltage: DC12 to 30V
Sensor life: 3 years
Explosion-proof form: probe transmitters and sensors are explosion-proof.
Explosion-proof rating: FTD6 II CT6
Connection cable: Three-core cable (single wire diameter 1.5mm);
Connection distance: 1000 m.
Protection rating: IP65.
Dimensions: 183X143X107 mm.
Weight: 1.5 Kg.
Detection of gases: |
Sulphur hexafluoride gas emissions from the air |
||
Detection range: |
0-100PPM,0-500PPM,0-2000PPM |
||
Resolution: |
0.01PPM(0-100PPM,0-500PPM)0.1PPM(0-2000PPM) |
||
How to display: |
LCD |
||
Temperature and humidity: |
Optional, temperature detection range: -40 to 120 degrees C, humidity detection range: 0-100%RH |
||
Detection: |
Diffusion, circulation, pump-suction options |
How to install: |
Wall-mounted, piped |
Detection accuracy: |
≤±3% |
Linear error: |
≤±1% |
Response time: |
20 seconds (T90) |
Zero-point drift: |
s plusmn;1% (F.S/year) |
Recovery time: |
20 seconds |
Resuscitation: |
≤±1% |
Signal output: |
(1) 4-20mA signal: standard 16-bit accuracy 4-20mA output chip, transmission distance 1Km |
||
Transfer: |
(1) Cable transmission: 3-core, 4-core cable, long-distance transmission (1-2 km) |
||
Receiving device: |
User computers, control alarms, PLCs, DCS, etc. |
||
Alarm: |
On-site sound and light alarm, external alarm, remote controller alarm, computer data acquisition software alarm, etc. |
||
Alarm settings: |
Standard configuration two-level alarm, optional three-level alarm, can be set alarm mode: regular high and low alarm, interval control alarm |