Hydrogen peroxide detector

  • No:SK-600-H2O2
  • Quantity:

      Recommend

    Hydrogen peroxide concentration detector

    Hydrogen peroxide gas concentration detection parameters
    Operating voltage DC24-plusmn;1% Baud rate 9600
    Measurement of gas hydrogen peroxide gas, detection principle electrochemical/infrared NDIR
    Sample accuracy and plusmn; 1%F.S. response time less than 30S
    Repetitive and plusmn;1%F.S. Working humidity 10-95%RH, (no condensation)
    Operating temperature -30 to 50 degrees C , long-term drift , plusmn; 1% (F.S/year)
    Storage temperature -40 to 70 degrees C , warm-up time 30S
    Operating current s 50mA s/o operating pressure 86kpa-106kpa
    Installation method Fixed installation , warranty period of 1 year
    Output interface A variety of shousing materials aluminum alloy
    Life of 2 years , size


    183 x 143 x 107mm (L x W x H) 1.5Kg (net weight of the instrument)
    The measurement range is detailed in the selection table
    Output signal TTL (standard) RS485, (general)/4-20mA
    Hydrogen peroxide gas leakage alarm device (SK-600-H2O2) is a modular design, intelligent sensor detection technology, the overall explosion-proofing (d) structure, fixed installation of toxic gas detector. Standard configuration with dot matrix LCD display, three-wire 4 to 20mA analog and RS485 digital signal output, optional configuration programmable switching output and other modules, according to user needs to provide customized products, but also support output signal fine-tuning and other functions, convenient system networking and maintenance.
    Characteristics
    Intelligent EC sensor, using intrinsic safety technology, can support multi-gas, multi-range detection, and can be customized according to user needs, no tools for sensor interchange, offline calibration and zero self-calibration
    Intelligent temperature and zero-point compensation algorithm, so that the instrument has better performance with good selectivity, avoiding interference from other gases to the detected gas
    A variety of signal outputs, which can be easily accessed to industrial control systems such as PLC/DCS, and can also be used as a stand-alone control
    Oversized dot matrix LCD display, support for Chinese and English interface
    No open cover, electrochemical/infrared NDIR remote control operation, single person maintenance
    Local alarm indication, all-in-one sound and light alarm (optional)
    The instrument has overrange and antipolar protection to avoid the danger caused by human improper operation
    Rich electrical interface for users to choose from
    By ATH2O2, UL, CSA and other certification, with international high-end quality
    Hydrogen peroxide gas leak alarm device product characteristics:
    Imported electrochemical/infrared NDIR sensorhaswith with good anti-jamming properties and a life of 8 years.
    Using advanced microprocessing technology, the response speed is fast, the measurement accuracy is high, the stability and repeatability are good.
    The detection site has the function of on-site sound and light alarm, the gas concentration exceeds the standard instant alarm, is the safety and security of the operation of dangerous places.
    4 field with backlit large-screen LCD display, visual display of gas concentration, type, unit, working status, etc.
    5 independent gas chamber, replacement sensor does not need on-site calibration, sensor key parameters automatically recognized.
    6 Full-scale range temperature digital automatic tracking compensation to ensure measurement accuracy.
    Hydrogen peroxide gas leakage alarm device technical parameters:
    Detection of gas: hydrogen peroxide gas emissions from the air
    Detection range: 0-5000PPM
    Rate: 0.1PPM
    Working mode: fixed continuous operation, diffusion, pipe, circulation, pump suction optional.
    Detection error: 1% (F.S)
    Response time: s 10S
    Output signal: current signal output 4-20MA
    Alarm mode: 2 passive node signal output, alarm point can be set.
    Working environment: -20 C to 50 degrees C (special requirements: (-40 C to 70 degrees C)
    Relative humidity: s 90%RH
    Operating voltage: DC12 to 30V
    Sensor life: 3 years
    Explosion-proof form: probe transmitters and sensors are explosion-proof.
    Explosion-proof rating: FTD6 II CT6
    Connection cable: Three-core cable (single wire diameter 1.5mm);
    Connection distance: 1000 m.
    Protection rating: IP65.
    Dimensions: 183X143X107 mm.
    Weight: 1.5 Kg.
    Detection of gas: hydrogen peroxide gas emissions from the air
    Detection range: 0-5000PPM
    Resolution: 0.1PPM
    Display Mode: LCD
    Temperature and humidity: Optional, temperature detection range: -40 to 120 degrees C, humidity detection range: 0-100%RH
    Detection mode: diffusion, circulation, pump suction optional installation mode: wall-mounted, pipe-type
    Detection accuracy: splusmn;3% linear error: splusmn;1%
    Response time: s20 sec (T90) zero drift: splusm; 1% (F.S/year)
    Recovery time: .20 seconds Resumability: splusmn; 1%
    Signal output: (1) 4-20mA signal: standard 16-bit accuracy 4-20mA output chip, transmission distance 1Km
    (2) RS485 signal: transmission distance 2Km using standard MODBUS RTU protocol
    (3) Voltage signal: 0-5V, 0-10V output, can be set by itself
    (4) Pulse signal: also known as frequency signal, frequency range adjustable (optional)
    (5) Switching signal: 2 relays standard, optional third set of relays, relay passive contact, capacity 220VAC 3A/24VDC 3A
    Transmission mode: (1) cable transmission: 3-core, 4-core cable, long-distance transmission (1-2 km)
    2 GPRS transmission: built-in GPRS module for real-time remote transfer of data, regardless of distance (optional)
    Receiving equipment: user computer, control alarm, PLC, DCS, etc.
    Alarm mode: on-site sound and light alarm, external alarm, remote controller alarm, computer data acquisition software alarm, etc.
    Alarm settings: standard configuration two-level alarm, optional three-level alarm, can be set alarm mode: regular high and low alarm, interval control alarm
    Electrical interface: 3/4"NPT internal thread, 1/2"NPT internal thread, support for 2 kinds of electrical connection