Six-in-one formaldehyde detector

  • No:WD-XK-A3C
  • Quantity:

      Recommend

    The scope of application of this instrument:
    Suitable for supervision, monitoring institutions, governance companies, decoration companies, construction companies, workshops and mines, can also be used for scientific research, teaching, laboratories.
    The applicable place of this instrument:
    Room, office, hotel, hotel, shopping malls and other places, the instrument appearance beautiful, easy to carry, suitable for on-site use.
    Features:
    Multi-functional: can detect indoor air formaldehyde, benzene, ammonia, toluene, xylene, TVOC harmful gases.
    Flow stability: In order to meet the needs of indoor environmental monitoring, the instrument uses large flow pump, adjustable resistance flow meter, with stable flow, high precision characteristics, can well adapt to benzene, ammonia, toluene, xylene, TVOC and other detection tubes have a large sampling resistance;
    Automatic control: easy to operate and intuitive at any set time. Set the sampling time in the control panel and stop working automatically at the end of the sample. High time accuracy, sampling error does not exceed 0.1 seconds;
    Date time, temperature indication: the panel can display the current date and time, show the temperature of the sampling environment, can visually reflect the environmental conditions of the sampling site.
    On-site determination of its body content, LCD screen full Chinese display.
    On-site thermal printing test reports in custom formats
    Light: This instrument is small in size, light in weight and easy to carry.
    Power supply: 220V AC, strong power, weak power independent control.
    Packing: The outer packaging of the instrument is a small aluminum suitcase.
    Technical indicators:
    1. Test items: formaldehyde, benzene, ammonia, toluene, xylene, TVOC
    2. Measurement range: formaldehyde (0.01 to 2.20mg/m)
    Benzene (0.05 to 4 mg/m)
    Ammonia (0.05 to 3mg/m)
    Toluene (0.05 to 4mg/m)
    Xylene (0.05 to 4 mg/m)
    TVOC(0.05~4mg/m)
    3. Flow range: 6X2.5 l/min
    4. Light source: LED silicon diode, wavelength 630nm
    5. Accuracy: splusmn; 10% reading, formaldehyde measurement accuracy splusmn; 0.01mg/m
    6. On-site thermal printing of test reports in custom formats.
    7. Traffic stability: greater than 95%
    8. Timing control: 0-60 minutes
    9. Power: 6X2.5W
    10. Power supply: 220V AC
    Machine features:
    Oversized LCD screen with backlight display.
    Full Chinese operating menu, easier to operate
    Provides the selection of different test execution criteria to facilitate the evaluation of test results
    On-site thermal printing test reports in custom formats
    Can be with the domestic model of formaldehyde detector for matching
    Solvether is generally a large six-in-one volume, not convenient to carry, but also need the shortcomings of the takeaway sampler, independent all-in-one machine design, convenient to detect carrying