Photon Portable Infrared Flue Gas Analyser
Measuring parameters:
Variable | Method | Range | Resolving power | Accuracy | Minimum detection limit | Reaction time (T90) |
Gas Measurements of Infrared Sensors: | ||||||
CO-CO, Volume concentration | Infrared Sensor | 0..2000 ppm 0...5 % | 1 ppm 10 ppm | 3 % rel. | 3 ppm 30 ppm | 45 seconds |
Carbon dioxide - Carbon dioxide, Volume concentration | Infrared Sensor | 0..25 % 0...1000 % | 0.01 % 0.1 % | 0.20 % | 0.20 % | 45 seconds |
NO-NO Volume concentration NO2-Nitrogen Dioxide N2O-nitrous oxide | Infrared Sensor | 0..1000 ppm 0...10000 ppm | 1 ppm 10 ppm | ± 1 ppm or 5 % rel. | 3 ppm 30 ppm | 45 seconds |
SO2 - SO2, Volume Concentration | Infrared Sensor | 0..2000 ppm 0...10000 ppm | 1 ppm 10 ppm | ± 5 ppm or 5 % rel. | 3 ppm 30 ppm | 45 seconds |
CH4 - Methane, Volume Concentration | Infrared Sensor | 0...5 % 0...100 % | 0.01 % 0.1 % | 0.20% | 0.20 % | 45 seconds |
Gas items of electrochemical sensors: | ||||||
O 2 - Oxygen, Volume Concentration | Electrochemical sensor | 0..25 % | 0.01 % | 0.20 % | 0.20 % | 45 seconds |
O 2 - Oxygen, Volume Concentration | Bias Voltage Sensor | 0..100 % | 0.1 % | 0.20 % | 0.20 % | 45 seconds |
NO2 - Nitrogen Dioxide, Volume Concentration | Electrochemical sensor | 0..1000 ppm | 1 ppm | ± 5 ppm or 5 % rel. | 5 ppm | 45 seconds |
H2S - Hydrogen Sulfide, Volume Concentration | Electrochemical sensor | 0..5000 ppm | 1 ppm | ± 5 ppm or 5 % rel. | 5 ppm | 45 seconds |
Cl2 - chlorine, volume concentration | Electrochemical sensor | 0...300 ppm | 1 ppm | ± 5 ppm or 5 % rel. | 5 ppm | 45 seconds |
H2 - Hydrogen, Volume Concentration | Electrochemical sensor | 0...1000 ppm | 1 ppm | ± 5 ppm or 5 % rel. | 5 ppm | 45 seconds |
Temperature measurement: | ||||||
Tgas - Smoke Temperature | Thermocouple type | -10..1000 °C | 1 °C | ± 2 °C or 1.5 % rel. | 1 °C | 30 seconds |
Tamb - Atmospheric Temperature | Thermoresistive type | -10..100 °C | 1 °C | ± 1 °C | 1 °C | 30 seconds |
Formula parameters: | ||||||
CO/CO2 | calculated value | 0...0.01 | 0.0001 | 0.0001 |
|
|
Lambda - Excess Air Volume | calculated value | 1..10 | 0.01 | 0.01 |
|
|
QA - Burning Loss | calculated value | 0..100 % | 0.1 % | 0.1 % |
|
|
Eta - efficiency | calculated value | 0..120 % | 0.1 % | 0.1 % |
|
|
Pressure measurement: | ||||||
Pressure/static pressure | DMS bridge | -25 hPa ... +25 hPa | 0.1 Pa | ± 2 Pa or 5 % rel. | 1 Pa | 10 seconds |
atmospheric pressure | DMS bridge | 800 mbar ... 1200mbar | 1 mbar | ± 5mbar or 2 % rel. | 1 mbar | 10 seconds |