细节展示放大镜特效

02 fire fighting suits Boots/hats/gloves, etc.

  • No:02
  • Quantity:

      Recommend

    Product name: 2002 type firefighter fire protection clothing 2002 type fire standard protective clothing

    Material combination: imported flame retardant fabrics, waterproof breathable layer, insulation layer, comfort layer, the use of DuPont reflective belt in the United States.

    Features: good insulation performance, good flame retardant performance, flexible, lightweight, set flame retardant, thermal insulation, waterproof, reflective, wet, comfortable in one, is in line with international standards of the new combat uniforms.

    Style: Split (top, pants).

    Specifications: S, M, L

    Purpose: Protective clothing worn by firefighters to protect their safety during a fire fight.

    This product conforms to ZGZ-ZPJY-001:2009 "Mandatory batch-by-batch inspection rules for firefighter fire protection clothing" and GA10-2002 Firefighter Fire Protection Clothing standards

    Type 02 fire clothing main technical parameters:

    1. Flame retardant performance: damage length of 100mm, fire-renewing time of 2S

    2. Breaks s 650N, tear ing-strength s100N, seam break-strength s650N

    3. Anti-static water pressure performance: hydrostatic pressure s 17000Pa

    4. Moisture resistance: water level is not less than 3 levels

    5. Tosmotor performance: transficaron volume of 5000g/m2 24h

    6. Thermal stability performance: after the test of 180 degrees C and plusmn;

    7. Overall protection performance: thermal protection capacity TPP value is not less than 28cal/cm2

    8. Clothing weight: 3.5kg

    Fire protection products - fire fighting clothing for Shanghai World's best-selling product line, if you have any on fire fighting clothing, fire boots, fire hats, fire gloves, fire belt and other related issues welcome to call Shanghai World Lift for you to demystify!

    Technical requirements for 02 fire fighting suits:

    5.1 Design requirements

    5.1.1 The structure of protective clothing Protective clothing is made of outer layer, waterproof breathable layer, insulation layer, comfort layer multi-layer fabric composite. This compound allows for the making of single tanders or jackets. And can meet the basic garment production process requirements and accessories corresponding to the standard performance requirements.

    5.1.2 Protective top

    5.1.2.1 Protected Area Protective tops should protect the upper torso, neck, arms and wrists of firefighters, but the scope of protection does not include the head and hands. The overlap between the protective top and the protective pants multi-layer fabric should not be less than 200mm.

    5.1.2.2 Collar Protective clothing should not be less than 102mm in height and should have buckled or fastened accessories. The structure of the collar should include an outer layer, a waterproof breathable layer and an insulation layer.

    5.1.2.3 The structure of the door flaps shall contain an outer layer, a waterproof breathable layer and an insulation layer.

    5.1.2.4 Cuffs should be designed to protect the firefighter's wrist and prevent burning debris from entering the sleeve. Cuffs must not interfere with the wearing of protective clothing and should be in conjunction with the wearing of protective gloves.

    5.1.3 Protective pants Protective pants should protect the lower limbs and legs of firefighters, but not ankles and feet.

    5.1.4 Reflective logo belt Reflective logo belt should be firmly stitched on the protective clothing top and pants, split protective clothing in the top chest, hem, cuffs, pants feet stitched width should not be less than 50mm reflective logo belt. The setting of the reflective flag belt should be visible in its 360-deg;

    5.1.5 Position of the label The label should be placed on the comfort layer on the left side of the front chest of the protective top.

    5.1.6 Color The color of the protective clothing is Tibetan blue.

    5.1.7 Accessories a) All hardware shall be spotless, knotted or sharp edges. And by corrosion treatment, b) should be used with flame retardant sewing thread and buckle, color and external layer material matching, c) protective jacket should be used at the front door of the connector not less than 8 zippers, color and external layer material matching, d) protective pants should be used for loose straps.

    5.2 Fabric Performance

    5.2.1 Outer

    5.2.1.1 Flame retardant performance Damage should not be greater than 100mm, the fire-continuing time should not be greater than 2s, and there should be no melting, drip phenomenon. 5.2.1.2 Surface moisture resistance Should not be less than level 3.

    5.2.1.3 Breaking Force E. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    5.2.1.4 Tear ing strong ethnoandreta, parallel tear strength should not be less than 100N.

    5.2.1.5 Thermal stability performance After the test of 260 degrees C and plusmn, the change rate of dimensions along the direction of longitude and latitude should not be greater than 10%, and there should be no significant change in the sample surface.

    5.2.1.6 Unit Area Quality Unit Area Quality should be rated by the fabric supplier with a rating of plusmn;5%.

    5.2.1.7 Color fastness Should not be less than 3 levels, water friction should not be less than 3 levels.

    5.2.2 Waterproof breathable layer

    5.2.2.1 Hydrostatic pressure resistance Hydrostatic pressure should not be less than 17Kpa.

    5.2.2.2 Permeable Vapor Performance The amount of water vapor should not be less than 5000g/(m2?24h).

    5.2.2.3 Thermal stability performance After the test of 180 degrees C and plusmn, the change rate of dimensions along the direction of longitude and latitude should not be greater than 5%, and there should be no significant change in the sample surface.

    5.2.3 Insulation

    5.2.3.1 Flame retardant performance Damage should not be greater than 100mm, the fire-continuing time should not be greater than 2s, and there should be no melting, driping phenomenon.

    5.2.3.2 Thermal stability performance After the test of 180 degrees C and plusmn, the change rate of dimensions along the direction of longitude and latitude should not be greater than 5%, and there should be no significant change in the sample surface.

    5.2.4 The performance of the comfort layer should not be molten or drip-drip.

    5.3 Overall protective performance The TPP value of thermal protection capacity should not be less than 28cal/cm2.

    5.4 needle distance density Sewing line straight, neat, flat, solid, tight suitable, light and dark line per 3cm should not be less than 12 needles, packet stitches per 3cm not less than nine needles.

    5.5 color difference protective clothing collar and predecessor, sleeve and predecessor, bag and predecessor, left and right predecessor should not be less than 4 levels, other surface parts should not be less than 4 levels.

    5.6 Seam break strength Protective clothing outer seam break strength should not be less than 650N.

    5.7 Reflective flag belt

    12.jpg