    Product Description:
    Finland's GASMET Dx4045 is a real portable on-site Fourier transform infrared gas analyzer. It applies laboratory analysis techniques to the detection of environmental gases or gaseous volatiles in emergency sites. GASMET Dx4045 is simple to operate, strong in structure and powerful in analysis. It is especially suitable for harsh site environment such as accidents, battlefields, emergency relief, accident disasters, health and epidemic prevention, fire fighting and so on. In the pollution accident scene, the type and concentration of pollutants can be measured in as short a time as possible with portable, simple and fast detection instrument. It includes the determination of gaseous and liquid pollutants.
    Product characteristics:
    The GICCOR high transmittance Michelson interferometer with patented technology is only the most reliable interferometer on the market today, and its robust structure exceeds the military vibration standard. Optical materials are moisture-proof and moisture-proof, and the air chamber is corrosion-proof. Direct sampling does not require sample pretreatment. There are two kinds of AC power supply modes with built-in rechargeable battery 220V. The operation of wireless PDA (Chinese interface) is simple and intuitive. The Chinese analysis software CALCMET has powerful functions. It can give quantitative analysis results of 50 groups at a time. It can also be used for rapid qualitative and semi-quantitative analysis of unknown gases.
    For emergency monitoring, the wireless Bluetooth PDA can sample and analyze rapidly and continuously, obtain quantitative analysis results of 50 gaseous components at one time, and store data and spectra simultaneously. PDA built-in digital camera and GPS, a person can measure the results, geographical coordinates, photos of the accident site sent to the scene command.
    All gases with spectral absorption in the mid-infrared range (600-4250 cm-1) can be simultaneously analyzed. In addition to diatomic eutectic molecules and inert gases (H and O ramming), most organic and inorganic gases can be analyzed. It can be widely applied to the analysis of various gases in the field environment.
    The gas chamber and mirror are coated with gold and rhodium to prevent the corrosion of corrosive gases. The multiple reflectance path is 9.8 M. It is specially designed for the field measurement of different compounds in low concentration air. The detection limit of most combinations is less than 0.5 ppm.
    Scanning speed is very fast, 10 times a second. Rapid analysis can choose 1 or 5 seconds, trace gas analysis can choose 3 or 5 minutes, and continuous sampling analysis can be carried out.
    CALCMET is a powerful analysis system, which can display the results of 50 components at one time. Users can customize range and concentration units. Provide real-time on-site spectral recording, automatic continuous timing storage, concentration-time trend map.
    Ex-factory calibrated components are calibrated by precise single component calibration to achieve accurate quantitative analysis. Each component can be calibrated at multiple points to ensure linearity. The calibration concentration can be from ppm level to percentage level. The accuracy of analysis is plusmn; 3%. Only one initial calibration is needed, and no further calibration is needed.
    Provide corresponding calibration packages for the users in different application fields for multi-component quantitative analysis. In case of special circumstances, it can also be calibrated according to user's needs. It is equipped with spectrum groups of gas components in unused application areas, which are used for qualitative search of unknown components and are constantly upgraded.
    CALCMET has many functions of searching and comparing spectral databases. It is convenient for users to search and characterize unknown gases quickly. CALCMET provides users to set alarm limits for each component by themselves. Field playback function is convenient for users to analyze and study the field in the future. The analysis results can be saved into text format, which is convenient for users to write analysis reports.
    Daily maintenance workload is very small and the cost is low. Clean maintenance and water calibration are required only once every two years on average.
    Product advantages:
    Direct sampling: Dx4045 does not need sample pretreatment, and the air pump built in the host directly extracts the ambient gas in the field. Hand-held samplers (built-in batteries, usable for 5 hours) can also be used to collect gases into sampling bags for further analysis.
    Various working modes: Dx4045 is suitable for modern soldier work, sample analysis, continuous vehicle testing, unattended testing and other working modes.
    Simple operation: Sampling, quantitative analysis and data storage can be completed by single-key operation of handheld wireless Chinese PDA.
    The software has powerful functions: GASMET analysis software CALCMET full-Chinese operation interface, with multi-gas quantitative, qualitative, unknown component determination, spectral library search, spectral matching, spectral storage, historical data playback, user self-calibration spectrum, self-built library, continuous measurement settings and other rich functions, making Dx4045 a field gas. A powerful tool for analysis.
    Quick multi-component quantification: The quantitative concentration values of 50 gaseous components can be given simultaneously in a few seconds.
    Rapid detection of unknown gases: NIST 5500 infrared spectrograms mass qualitative search, Gasmet 300 qualitative and semi-quantitative spectrograms.
    Low detection limit: The sample chamber of Dx4045 has a light path of 9.8 meters, and a high sensitive MCT (low temperature, no refrigerant semiconductor refrigeration can be achieved - 37 C) detector is used, which makes the detection limit of most gaseous components less than 0.5 ppm.
    Low operating cost: Dx4045 needs no other consumables besides the calibration of nitrogen for accurate quantification.
    Sample chamber: Rhodium coating, anti-corrosion
    Window Material ZnSe: Moisture-proof
    Built-in rechargeable battery, shoulder-back type: easy to use on site

    Built-in air pump: 2.0L/min

    Technical Indicators of Products:
    1) Principle: Fourier transform infrared analysis principle.
    2) Field adaptability: completely portable, strong seismic performance, suitable for field work.
    3) Working environment: temperature - 5 ~40 C, humidity 0~80%.
    4) Computer configuration: to meet the needs of software analysis, no less than Wind7 system, support mouse, USB port, keyboard and network transmission and data storage functions.
    5) Qualitative and quantitative analysis.
    6) Chinese analysis software can display not less than 50 gas components at a time.
    7) The built-in rechargeable batteries can be used. Each recharge of the batteries can last more than 2 hours. The instrument can also use 220V AC power supply.
    8) Have a formal certificate of approval for the type of measuring instruments.
    Technical parameters of products:
    Spectral analysis range: 600-4250 cm-1
    Luminance: 9.8m
    Monitor: (Semiconductor Refrigeration) MCT
    Mirror: Gold and Rhodium Coatings
    Response time T90: less than 60s
    Hand-held sampling strong, built-in dust filter
    Hand-held controller PDA: color LCD touch screen, waterproof, dust-proof, magnetic-proof, digital camera, GPS call function (need SIM card)
    PDA operation software CALCMET Lite in Chinese, displaying 50 component detection results at the same time, storing sample spectrograms
    Computer analysis software: Chinese CALCMET Pro can simultaneously analyze 50 components at one time, and the unknown multi-component qualitative spectrum can be stored, replayed and reported out continuously.
    Quantitative calibration includes: anti-terrorism, chemical warfare, emergency, commodity inspection, occupation, health, hospital, fire protection, etc.
    Qualitative Search Library: GASMET 300 + Semi-Quantitative, NIST 5500 Components
    Spectral resolution: 4cm-1 or 8cm-1
    Beam splitter: Znse (moisture-proof)
    Indicative error: Plussmn of corresponding scaling range; 3%
    Sampling flow: 2.0L/m
    Communication Interface: Bluetooth, RS-232, USB
    Infrared Light Source: SiC, Ceramic Component
    Working temperature: - 10 ~50 C humidity: 0~90% storage temperature: - 20 ~60 C, extreme: - 55 ~75 C
    Power supply: 12V DC built-in rechargeable battery, full charge can be used continuously for more than 4 hours or 220V AV
    Waterproof and shockproof portable chassis: DEF-STAN-81-41, IP69 certification
    Data analysis and processing system:
    Qualitative and quantitative ex-factory calibration spectral library for not less than 50 components:
    1, water; 2, carbon dioxide; 3 carbon monoxide; 4, nitrous oxide; 5, nitric oxide; 6, nitrogen dioxide; 7, sulfur dioxide; 8, ammonia; 9, hydrogen chloride; 10, hydrogen cyanide; 11, hydrogen fluoride; 12, methane; 13, ethane; 14, ethylene; 15, propane; 16, (n) hexane; 17, cyclohexane; 18, benzene; 19; Toluene; 20, styrene; 21, m-xylene; 22, o-xylene; 23, p-xylene; 24, acetic acid; 25, formaldehyde; 26, acetone; 27, methanol; 28, ethanol; 29, phenol; 30, dichloromethane (Freon 30); 31, chloroform; 32, 1, 1-dichloroethane; 33, 1, 2-dichloroethane (Freon 150); 34, trichloroethane Ethylene; 35, tetrachloroethylene; 36, phosgene; 37, methyl acetate; 38, ethyl acetate; 39, methyl propionate; 40, trimethylamine; 41, nitrobenzene; 42, chlorobenzene; 43, ethylbenzene; 44, acrylonitrile; 45, carbon disulfide; 46, aniline; 47, vinyl chloride; 48, propylene dilute aldehyde; 49, acetaldehyde; 50, acetic anhydride.
    Optional measurement time
    Fifteen kinds of chemical warfare agent pools can be selected
    Error Range: Plussmn of Bidding Range; 5% (Bidding Documents need CPA Certification and Evaluation Report)
    Automatically locating and judging unknown gases
    Selection of multiple analytical ranges for different applications
    Can output test data to text format and use EXCEL for report analysis
    Arbitrary conversion between ppm and mg/m3
    Chinese Software Interface
    Upgradable Reference Spectrum Library
    Continuous on-site recording and storage, automatic storage of measurement spectrograms

    Quantitative analysis: Quantitative analysis of not less than 50 components at the same time. Qualitative spectral library of more than 5000 components is provided. Quick qualitative and semi-quantitative analysis of unknown gas components can be carried out.

    Manufacturer Certificate and Product Certificate:
    We are the manufacturer of precision instruments. Our products are used for environmental compliance monitoring, process control, health and safety applications. Gasmet maintains a high level of quality and the latest products are certified in many countries.
    ISO 9001 Quality System Management Certification
    Gasmet Oy meets the technical quality management standard ISO 9001:2008 in the following areas: design, manufacture, sales and service of gas analysis equipment.
    EN 15267-3 Quality Certification
    EN 15267 is a European Standard for Quality Assurance Continuous Emission Monitoring System (CEMS) and its Part 3 (EN 15267 - 3) Processing Performance Standards and Testing Procedures. Gasmet gas analyzer passed the test and certification.
    German Tü V Component Product Safety Certification
    Gasmet CEMS, CEMSII continuous emission monitoring system has been tested and certified in accordance with the TUV certification process of Rhine in Germany and EN 15267-3.
    Product Compliance Certification of the MCERTS Monitoring Certification Scheme of the Environment Agency of England and Wales
    Gasmet gas analyzer testing and certification, that is, through SIRA in accordance with EN 15267-3 provided by the analysis program using Gasmet sampling system provided by the analysis program.
    Russian GOST Compulsory Safety Certification of Soviet National Standard Market Access
    Pass CPA (National Quality Supervision of Analytical Instruments) Certification
    Fourier infrared gas detector, through the evaluation report of measuring instrument type issued by the National Quality Supervision and Inspection Center of Analytical Instruments, the results show that the measurement accuracy is all qualified.
    Pass CE certification
    Related links
    Example 1: Kim Jong-un's brother Kim Jong-nam died of VX neurotoxic poisoning in Malaysia (Gasmet Chemical Warfare Agent Bank can detect VX neurotoxic agent)