细节展示放大镜特效

Portable poison alarm

  • No:nothing
  • Quantity:

    Product Profile:

    Portable poison alarm belongs to C-test neurotoxic agent. The product of alarm sensitivity and response time is P-permissible.

    Purpose: Phosphorus poison alarm is a portable instrument used by the central (part) of the synthetic army under field conditions. It is mainly used to monitor the air poisoning caused by the attack of the enemy using phosphorus poison. When the air poisoning reaches a certain level, it will send out alarm information by sound and light.

    Technical parameters:

    Use environment

    It can work normally in the environment of - 20 + 40 C, relative humidity 95% & plusmn, 5% (at 30)

    sensitivity

    Normal temperature: alarm within 5 seconds when sarin concentration is less than 1.5 mg/m3; alarm within 5 seconds when VX concentration is less than 3 mg/m3

    Low temperature, high temperature, humidity and heat: alarm within 5 seconds when sarin concentration is less than 1.5 mg/m3; alarm within 10 seconds when VX concentration is less than 4 mg/m3

    Air flow rate

    Sample gas flow rate is 500-900ml/min

    Working stability

    The instrument runs continuously for 2 hours after start-up under the prescribed environmental conditions, and there is no outage or false alarm.

    Drying resistance

    The instrument does not misreport the smoke of low concentration of nitrate, automobile engine exhaust and soot under field conditions. Tobacco and wood tobacco should be avoided if they are dry to instruments.

    Power supply and working time

    The instrument is powered by a rechargeable lithium battery pack. When the battery pack is fully charged, it can be used continuously for more than 6 hours at room temperature and for more than 4 hours at low temperature, high temperature and humidity.

    Sealability

    The rubber sealing cap is used to cover the air intake, exhaust nozzle, charging socket, sound device and other parts to prevent rain. Other specific waterproofing measures should be taken when feces are immersed in water.

    Shape size

    134* 93* 43(excluding prominent parts)

    weight

    ≤900g

    Composition of 0 poison alarm

    The poison alarm is mainly composed of main engine, charger, leather cover and so on.