Home>Equipment list>Protective equipment>Nuclear and biochemical protective equipment>Anti-Filtration of Aniline Harmful Gases by Xinhua Chemical Technology Grade 3 Gas Filtration Tank
细节展示放大镜特效

Anti-Filtration of Aniline Harmful Gases by Xinhua Chemical Technology Grade 3 Gas Filtration Tank

  • No:P-A/B/E/K-3
  • Quantity:

      Recommend


    Self-priming filter for gas mask

    First,purpose

    When complying with all instructions, restrictions and applicable safety and health regulations, the filters and air filters can be used in conjunction with full or half masks of self-priming filter gas masks to provide limited respiratory protection in the corresponding air pollution areas.

    Not applicable to:The concentration of pollutants is too high or unknown.

    Not applicable to:The oxygen content in the air is lower than that in the air.18%Environment, escape from underwater operation and fire protection zone.

    Not applicable to:Closed working environment, such as wells, tanks or relatively sealed environment.

    Two.Protection time

    Type of filter

    A

    B

    E

    K

    CO

    Hg

    H2S

    GH2O

    Standard color

    brown

    gray

    yellow

    green

    white

    red

    blue

    powder

    Examples of Protected Objects

    Benzenes, anilines,

    Carbon tetrachloride,

    Nitrobenzene and Bitter Chloride

    hydrogen chloride

    Hydrocyanic acid and chlorine

    sulfur dioxide

    ammonia

    Carbon monoxide

    mercury

    Hydrogen sulfide

    formaldehyde

    Test medium

    benzene

    Hydrocyanic acid

    (hydrogen chloride)

    sulfur dioxide

    ammonia

    Carbon monoxide

    mercury

    Hydrogen sulfide

    formaldehyde

    1level

    Test Brochure
    Mass concentration(mg/L)

    5

    1.1

    0.6

    2.7

    0.76

    5.8

    0.01

    1.4

    2.4

    Protection time(min≥)

    45

    25

    22

    25

    25

    20

    2000

    35

    30

    2level

    Test Brochure
    Mass concentration(mg/L)

    9.7

    3.4

    1.1

    8

    2.1

    5.8

    0.01

    4.2

    4.6

    Protection time(min≥)

    70

    27

    23

    23

    25

    27

    3000

    35

    30

    3level

    Test medium concentration(mg/L)

    16.2

    5.6

    3

    13.3

    3.6

    5.8

    0.01

    7.1

    5.5

    Protection time(min≥)

    115

    63

    50

    30

    55

    100

    4800

    110

    50

    Penetration concentration(ml/m³)

    10

    10a

    5

    25

    50

    0.1

    10

    10



    Three.Instructions

    1Before use, please read this manual carefully to check whether the type of filter is consistent with the protective gas in the polluted area, and check the connection between the filter and the mask. Users are obliged to conduct pre-job training for users.

    2The filter is easy to absorb moisture. It is not allowed to open the package, unscrew the lid or the bottom plug before use. The filter is not recommended to be reused.

    3Due to the influence of temperature, humidity and pollutant concentration in the polluted area, the protection time of the filter is only used as a reference value. If you smell odor or dizziness, nausea, dyspnea, etc., you should immediately evacuate the polluted area and check or replace the filter or respirator.

    4Special attention should be paid to the protection of colorless, odorless and harmful gases (such as mercury, carbon monoxide, etc.) and they should be accompanied by operations.