细节展示放大镜特效

Intelligent X-ray and gamma-ray radiometer

  • No:REN500A
  • Quantity:

      Recommend

    REN500A Intelligent and gamma-ray radiometer uses highly sensitive scintillating crystals as detectors. It has fast reaction speed and wider range of dose rate measurement compared with similar instruments in China. This instrument can not only measure high energy and low energy gamma rays, but also measure low energy X-rays accurately. It has good energy response characteristics. In addition, the stored data can be read out and analyzed by the complementary RenRiRate dose rate management software. The instrument is widely used in environmental protection, metallurgy, petrochemical industry, chemical industry, health and epidemic prevention, import and export commodity inspection, radioactive laboratory, scrap iron and steel, commodity inspection, various radioactive workplaces and other occasions requiring radiation environment and radiation protection detection.
    Characteristic:
    1. High sensitivity, wide measurement range, good energy response characteristics.
    2. High-speed micro-power microprocessor unit.
    3. Numbers and scales show the state of dose rate.
    4. Bilingual menu interface in Chinese and English.
    5. Digital LCD display with high backlight function.
    6. It can store 800 dosage rates and check them at any time without losing power.
    7. USB data interface, which can upload data to the computer.
    8. Dose rate and cumulative dose can be measured.
    9. The sound and light alarm function after the dose rate exceeds the threshold.
    10. Over-threshold alarm, blocking alarm, detector fault alarm function.
    11. Real-time display of battery power.
    12. Standardization: RenRiRate software.
    13. Suitable for Low Range and Environmental Level Radiation Detection
    Technical Indicators:
    1. Detector: 30*25mm, NaI(TL) scintillating crystal
    2. Measurement Range: Dose Rate: 0.01-500.00-micro; Sv/h
    Cumulative dose: 0.00-9999 mu Sv
    3. Sensitivity: 1 uSv/h>350 CPS
    4. Energy threshold: 35 Kev
    5. Energy response: 48 Kev~3 Mev <± 30%
    6. Relative error: 7. Measuring time: 1-120 seconds programmable setting
    8. Alarm threshold: 0.25, 2.5, 10, 20 (mu Sv/h) or self-setting
    9. Display unit: dose rate: mu Sv/h, mu Gy/h, mu R/h; cumulative dose: nSv; counting rate: CPS
    10. Communication: USB communication interface. The instrument can store 800 pieces of data and export them to RenriRate software.
    11. Use environment: temperature - 10 C to + 50 C, relative humidity (at 40 C) less than 95%.
    12. Power Supply: 2 Standard No. 1 Batteries
    13. Power Consumption: Power Consumption < 120 mW (excluding display backlight)
    14. Weight and size: 1.8Kg (including batteries); 42*23*15 (cm)
    RenriRate Radiation Dose Management Software Provides Text Table and Curve Graphic Display