细节展示放大镜特效

On-line Radiation Safety Alarm Instrument

  • No:REN300A
  • Quantity:

      Recommend

    REN300A on-line radiation safety alarm is a new type of x-gamma radiation continuous monitoring and alarm device. It uses a special designed preamplifier circuit. It has the characteristics of high sensitivity, easy operation, automatic display and ultra-threshold alarm. It can give the radiation dose rate of x-gamma in real time. Considering the need of field operation and emergency response, the host computer is installed in the radiation field to realize real-time monitoring and local alarm, and the automatic monitoring of the general control room is realized by RS485 communication. RenriArea radiation area monitoring software can be selected according to field requirements. The software can store historical data of 30 probes for more than 5 years continuously, and provide real-time data acquisition and spectra.
    The instrument is widely used in radioactive waste depots, industrial non-destructive testing, gamma knife treatment, isotope application, gamma irradiation, hospital X-ray diagnosis, accelerator, Xray device, nuclear power plant and other radioactive sites. It reminds staff that the radiation source or radiation device has been working or leaking, so as to protect them from radiation hazards.
    I. Characteristics:
    1. High-speed embedded microprocessor, LED display and humanized input are adopted.
    2. A host can hang up to five detectors; failure indication occurs when abnormality occurs.
    3. Multiple output and input interfaces can be interlocked with X-Ray or lead gate.
    4. Wall-mounted main control box, easy to install.
    5. Communication modes:
    Host and probe: standard RS485/232 interface, MODBUS communication protocol transmission distance up to 800 meters;
    Host and other devices: serial or network ports (optional) output to the computer or other devices.
    6. Radiation monitoring system can be formed with RenriArea Radiation Area Monitoring Software
    II. Technical Indicators:
    1. Detector: GM tube detector (energy compensation)
    2. Measuring range: 0.01 mSv/h~2500 mSv/h
    3. Sensitivity: 1 uSv/h greater than 5 CPS
    4. Display unit: mu Sv/h or mSv/h
    5. Response time: 1S (processed by algorithm)
    6. Relative inherent error: 7. Energy response: 48 Kev-1.5 Mev (& plusmn); 30%
    8. Display mode: LED display
    9. Probe configuration: up to five probes can be connected
    10. Output signal: The host can output active (or passive) normally open (or normally closed) signals.
    11. Other functions: External alarm lamp, probe waterproof treatment to IP67
    12. Communication: Standard RS485/RS232 communication, MODBUS communication protocol; Host equipped with network ports, optional network communication
    13. Power supply: 220V municipal power supply
    14. Use environment: temperature - 10 C to + 50 C, relative humidity (at 40 C) less than 95%.
    15. Size: Host: 280*220*92 (excluding base);
    Probe: _50*185 mm