Product Profile:
AT1117M neutron radiation detector is a hand-held instrument. It is mainly used to measure the radiation dose rate and dose of neutron. Besides, there is a GM counter in the host, so it can also measure the radiation dose rate and dose of gamma.
Product Principle:
The neutron probe transmits the measurement data to the host computer for processing, and the final measurement results are displayed on the host screen. Users can store measurement data manually. Instrument arithmetic guarantees the continuity of measurement and can analyze the measurement results in real time.
Product applications:
Dose monitoring in nuclear power plants, manufacturing plants, scientific research laboratories, medical institutions, etc.
Product characteristics:
Rapid adaptation to changes in radiation levels
Wide energy range
Sound and light alarm signals
Self checking
The measurement results can be stored in the instrument.
It can be used in bad weather.
Containing components:
Host
Neutron probe
Product parameters:
Radiation types | Host | Gamma radiation |
probe | Neutron radiation | |
detector | Host | GM counter |
probe | 3He proportional counter | |
Energy range | Host (gamma) | 60 keV ... 3 MeV |
Probe (n) | 0.025 eV…14 MeV | |
dose rate | Host (gamma) | 1 μSv/h ... 10 mSv/h |
Probe (n) | 0.1 μSv/h ... 10 mSv/h | |
dose | Host (gamma) | 1 μSv ... 1 Sv |
Probe (n) | 0.1 μSv ... 10 Sv | |
Energy Dependence (137Cs 662keV) [Host] | - 25%...+35%(energy range 60 keV-3 MeV) | |
Sensitivity (137Cs gamma radiation) [host] | 1.0 cps/μSv·h-1 | |
Response Time of Dose Rate Measurement (Dose Rate (> 10 mSv/h) [Host (gamma)] | Less than 2 s (accuracy error < plusmn; 10%) | |
Sensitivity (Pu-Be Neutron Radiation) [Probe] | 0.355 cps/μSv·h-1 | |
Measurement range of neutron flux density [probe] | 0.1 – 104 n·s-1·cm-2 | |
Sensitivity (Pu-Be Neutron Radiation) [Probe] | 0.5 cps/(n·s-1·cm-2) | |
Inherent relative error | Dose rate measurement: & plusmn; 35%* dose measurement: & plusmn; 35%* Neutron flux density measurement: & plusmn; 20% comment: * for Pu-Be source | |
Duration time | ≥24 h | |
Working temperature range | -30°С ... +50°С | |
Burn-up Life | ≥100 Sv | |
Protection Level | IР64 | |
Power supply | Built-in rechargeable battery + 12V external power supply 220V 50Hz external power supply | |
size | Host | 200х85х36 mm, 0.5 kg |
probe | ?90х290 mm,2.0 kg | |
The radiation detector meets the following international standards: The following safety standards are met: |