Home>Product list>Security check>Drug, gas, liquid, biochemical detection equipment>The three model of human body drug addict traces detector
细节展示放大镜特效

The three model of human body drug addict traces detector

  • No:Bioesens600
  • Quantity:
    Best Trace Detector for Drugs, Explosives and Drug Addiction Detection

    BIOSENS® 600 detects explosives and drugs from a sample with a very low false alarm rate, quickly and sensitively, and collects pads to collect samples of luggage, parcels, goods, vehicles, clothing, hands and other areas.

    The collection pad can also be used to collect samples of unknown substances and liquids.


    Drug abuse testing

    In addition to being able to detect traces of drugs and explosives, BIOSENS® 600 is also used to detect drug abuse among people.

    Using sticks to collect mucus from saliva and tongue coat surfaces can make the detection range much wider than that of simple saliva samples.

    Through sweat sample analysis, to determine whether the person under test is taking drugs in the near future

    By analyzing the hair samples, we can judge whether the subjects have a history of drug abuse or not.

    Improving the Probability of Detection

    The combination of trace detection and drug abuse detection can greatly increase the possibility of detecting drug smugglers, including drug carriers and drug addicts in vivo; one sample is used for traces and sweat, and the other sample is used to detect oral fluids and tongue coating mucus.
    Multipurpose Detection System
    The BIOSENS® 600 is unique in that a device can provide trace detection, substance identification, liquid identification and drug abuse detection. Whether the customer needs one or more applications, the operator can easily implement it through the configuration menu.
    Three different sampling tools are available
    Customers can choose from three sampling tools:
    & Middot; a disposable collection pad used to collect traces and sweat samples
    & Middot; Recyclable acquisition pad for trace detection, solid and liquid identification
    & Middot; oral collecting rod for oral fluid and tongue coating mucus
    Non-invasive, hygienic sample collection
    When collecting oral and sweat samples, the staff can observe the collection process on site, thus greatly reducing the risk of forgery samples.
    Effective and unique Biotechnology
    Behind BIOSENS® 600 is a team of researchers and developers from well-known institutions who integrate organic chemistry and surface chemistry, immunology and microfluidics into a unique detection system - with a humanized design.
    The heart of BIOSENS® 600 is a Surface Acoustic Wave (SAW) chip that allows the device to detect both drugs and explosives.
    Very low false alarm rate
    Due to the use of immunology-based detection technology, BIOSENS® 600 can provide very low false alarm rate detection in the world.
    Touch screen
    The LCD screen with panchromatic display ensures accurate and reliable presentation of test results. Information can be input directly through the touch screen or through an external keyboard. Language categories can be customized to customer needs
    Easy to operate
    BIOSENS® 600 is easy to carry and only takes 10 minutes from opening to running. The built-in thermal printer effectively avoids the misunderstanding of the test results. The user interface has multiple language choices and provides data archiving management. Providing visual and voice informers
    Drug detection
    Classification of substances: amphetamine, methamphetamine/deoxyephedrine, MDA malondialdehyde, MDMA ecstasy pills, ecstasy drugs, ephedrine hydrochloride, pseudoephedrine, cocaine, hallucinogens, opium, THC tetrahydrocannabinol, ketamine and derivatives of these substances
    Explosive Detection
    TNT, DNT, Tetryl, RDX, PETN and NG and their derivatives
    Power requirements
    Power supply requirements: 100-240 V 50/60 Hz
    Vehicle Installation: 12/24 V DC
    Power: 50W
    Data preservation and connectivity
    Data transmission: Ethernet, USB
    Data Storage: More than 1.000,000 results can be stored
    Implementation criteria
    Routine: CE mark, WEEE, RoHs
    Standards: IEC/EN 61010-1, EN 61326 (1997), UL 61010B-1, CAN/CSA-22.2, No. 1010.1-92, 1992, PSE
    Produced by Swedish Biosensor Applications International AB Company
    Overview
    Product Description: Portable Device for Rapid Field Drug Addiction Detection and Trace Detection
    Model: BIOSENS® 600
    Detection Technology: Immunoassay Reaction Based on Sound Chip Sensor
    Preheating: 10 minutes
    Analysis time: 30-60 seconds
    Calibration time: 30-60 seconds
    Printer: built-in thermal printer
    Size: 40 x 23 x 35 cm (16 x 9 x 14 inches)
    Weight: 14 kg. (30 pounds)
    Portability: built-in handle
    environment condition
    Work: 10 to 40 C (50 to 104 F); Storage: & plusmn; 0 to 60 C (32 to 140 F)
    Humidity: 95%, non-condensation
    Display
    Display screen: 6.4 inch color LCD touch screen
    Consumables Status: Detail Indicator
    Warning: Sound and Image
    Language: Applicable to any language
    control
    Detection mode: traces, mouth, substance & amp; liquid
    Test data: free text and barcode
    Consumables replacement inspection: automatic