细节展示放大镜特效

Multifunctional Radiometer

  • No:inspector+
  • Quantity:

      Recommend

    A, B, Gamma and_Multifunctional Radiometer/Radiometer
    It provides you with a fast, accurate and convenient means of radiation detection. It can be used not only for radiation dose rate detection but also for surface contamination measurement. This product adopts GM detection method to monitor radioactive workplaces and surfaces. It is a high cost-effective radiation for measuring alpha, beta, gamma and X radiation contamination counts and environmental dose rate of laboratory workplaces, floors, walls, hands, clothes and shoes. Radiometric instruments. Commonly used for:

    1. Check local radiation leakage and contamination.

    2. Check the radon radiation in the surrounding environment;

    3. Check the radioactivity of stone and other building materials;

    4. Check landfills and garbage dumps with nuclear radiation risk;

    5. Measure the X-ray radiation intensity of X-ray instruments from medical to industrial use.

    6. Check the pollution of radium in groundwater;

    7. Check the radioactivity of underground drilling pipes and equipment;

    8. Monitoring air and water pollution around nuclear reactors;

    9. Check the harmful radiation of personal valuable property and jewelry;

    10. Check the radioactivity of porcelain, tableware, glass, etc.

    11. Accurate location of radiation sources;

    12. Home decoration inspection.

    Technical performance and characteristics:

    1, 4-bit liquid crystal display

    2. Detection of alpha, beta, gamma and X-ray

    3. Counting Measurement, Total Counting Measurement and Dose Rate Measurement

    4, 1 minute-24 hour timing measurement

    5. Minimum response energy: 20 Kev (X, gamma rays)
    Lower detection limit: 0.02 microhabitat for I-125;

    6. Efficiency (4pi): Under contact: about 38% for Sr-90 source, 5.3% for C-14 source, 33% for P32 source, and 3% for Co-60 source.

    7. G-M counter, effective diameter 45 mm, mica window density 1.5-2.0 mg/Cm³

    8. Accuracy of <500 Sv/h, range of 15%, range of 200-1000 Sv/h 20%;
    CPS: <15% in the range of <2500 CPS and <20% in the range of 2500-5000 CPS.

    9. Measuring Unit: Commonly Used Unit (Mr/h or CPM) or SI Unit (USv/h or CPS) of the Detector

    Technical parameters:

    1. Measurement range:

    mR/hr: .001 to 100.0

    CPM: 0 to 350,000

    Total: 1 to 9,999,000 counts

    µSv/hr: .01 to 1,000

    CPS: 0 to 5,000

    2. Efficiency (4pi): Contact:

    β:

    C-14 (49 keV avg. 156 keV max.): 5.3%
    Bi-210 (390 keV avg. 1.2 MeV max.): 32%
    Sr-90 (546 keV and 2.3 MeV): 38%
    P-32 (693 keV avg. 1.7 MeV max.): 33%

    α:

    Am-241 (5.5 MeV): 18%

    The sensitivity of gamma to Cs-137 source is 5.8Cps/mSv/h, and the detection limit is 0.02 for I-125.

    3. Timer:

    Sampling cycles within 1-10 minutes were set in increment of 1 minute.

    Sampling cycles within 10-50 minutes were set in increments of 10 minutes.

    Sampling cycles within 1-24 hours were set up with an increment of 1 hour.

    4. Accuracy: mu Sv/h: < 500 mu Sv/h; range < 15%, range < 20% in 500-1000 mu Sv/h;
    CPS: <15% in the range of <2500 CPS and <20% in the range of 2500-5000 CPS.

    5. Temperature range: -10-+50 ~C

    6. Size: 150 x 80 x 30 mm

    7. Weight: 323g

    8. Power supply: 9V alkaline battery, working 200 hours under normal background and 24 hours under 10 mSv/h;