Home>Equipment list>Security check>Morphine+Methamphetamine Dimer Detection Reagent
细节展示放大镜特效

Morphine+Methamphetamine Dimer Detection Reagent

  • No:Drug Detection Card
  • Quantity:

      Recommend

    Morphine (heroin, opium)+ Methamphetamine (methamphetamine) in one


    [original Li]Colloidal gold immunochromatographic technique was used to coat drug antigens on nitric acid fibers and specific antibodies labeled with colloidal gold on glass fibers. At the time of detection:

    1. If there is no morphine, methamphetamine or its metabolites in the sample, the specific antibody labeled with colloidal gold binds to the membrane antigen to form three red lines: a quality control line C, a morphine response line MOR and a methamphetamine response line.METThe results showed that both morphine and methamphetamine were negative.

    2. If there are morphine, methamphetamine or their metabolites in the samples, and the concentration is higher than the detection level (morphine is higher than 300 ng/ml, methamphetamine is higher than 300 ng/ml).1000ng/ml) When the drug molecule competes with the colloidal gold labelled antibody, it prevents the colloidal gold labelled antibody from binding with the membrane antigen, and makes the corresponding red reaction lines disappear (MOR, MET reaction lines disappear), only a red quality control line (C) appears, indicating that the results of the test are positive for morphine and methamphetamine.

    3. If there is only morphine or its metabolites in the sample, but no methamphetamine and its metabolites, and the concentration is higher than the level of morphine detection (300ng/ml), the corresponding red reaction line MOR disappears and only the quality control line (C) and methamphetamine reaction line appear.(METThe results showed that morphine was positive.

    4. If there is only methamphetamine or its metabolites in the sample, but no morphine and its metabolites, and the concentration is higher than the detection level of methamphetamine (1000ng/ml), the corresponding red reaction line will be obtained.METOnly quality control line (C) and morphine response line appeared.(MORThe results showed that methamphetamine was positive.

    5. If there is no quality control line (C) in the test result, no matter whether there is morphine response line or not.(MORMethamphetamine reaction line(METThe test results are considered invalid and should be re-tested.

    The card is simple to operate and does not need any instruments and equipment. It can detect morphine, methamphetamine and its metabolites in human urine quickly and sensitively. It is especially suitable for drug rehabilitation centers, hospitals, drug abuse census, entertainment inspection, military conscription and physical examination of unit recruits.

    [Kit Composition]1. Instructions:1share 2Detection Card:40person-portion/box 3Pipette:40branch

    [Sample requirements]urine

    [Operating steps]Open the sealed aluminium foil bag, take out the required test card, place it flat at room temperature, and use plastic straw to absorb it.2~3Dropping urine samples (60-80 ul) were slowly dripped into the sampling hole. The results were observed within 3-5 minutes and exceeded 5 minutes. The results were invalid.

    [Notes]

    1. The test card should be used as soon as possible after it is removed from the aluminium foil bag. Exposure to air for too long will affect the results.

    2. Sample containers should be clean, dry and free of any preservatives.

    3. New sample containers and pipettes should be used in each experiment to avoid cross-contamination of samples.

    4. If the specimen cannot be sent for examination in time, place it.4Preservation at C48Hours; long-term preservation can be frozen in-20Temperature, avoid repeated freezing and thawing.

    5. Samples should be balanced to room temperature after removal from the refrigerator; if the sample is turbid, it should be filtered, centrifuged or naturally precipitated, and supernatant should be taken in the experiment.

    The results were judged within 6.3-5 minutes and were invalid after 5 minutes.

    7. Beware of damp detection card. After damp detection card or broken aluminium foil bag, the detection card can not be used.

    8. Aluminum foil bag contains desiccant, so it should not be taken by mistake.

    [Storage conditions]4~30Storage in a cool and dry place at C

    There are effect Period]18 months