Home>Equipment list>communication device>C-net Telecom Version GPS Satellite Positioning Anti-theft Device
细节展示放大镜特效

C-net Telecom Version GPS Satellite Positioning Anti-theft Device

  • No:ks189
  • Quantity:

      Recommend


    Chewushi GPS positioning terminal KS189

    Product Specification

    (Version V1.0)


    Please read the product specifications (including installation instructions) carefully before use in order to get the correct installation method and fast operation. If the appearance and color of the product are changed, please refer to the actual object.


    Catalog

    I. Product Overview

    II. Product Pictures

    III. Product Function

    IV. Principles of Products

    Technical Specifications

    VI. Product Accessories

    Installation instructions

    VIII. Usage

    IX. Notes

    10. After-sales Service




    I. Product Overview

    KS189 is based on CDMA2000 1X network and GPS (Global Satellite Positioning System), which locates or monitors long-range targets through short message or internet. The product has the functions of mileage statistics, ACC detection, power off alarm, etc. It is compatible with the original car anti-theft device, that is, after the car anti-theft device alarms, the device also sends out alarm information immediately and notifies the owner by short message.


    II. Product Pictures



    III. Product Function

    1. Administrator Number Settings

    2. Authorization Number

    3. Password Management

    4. Mobile Location

    5. Platform positioning

    6. Remote Control of Oil Circuits and Circuits

    7. Remote Monitoring

    8. Electronic fence

    9. Motion Alarm

    10. Overspeed alarm

    11. Power off alarm

    12. Emergency Alarm

    13. Mileage Statistics

    14. Equipment Restart


    IV. Principles of Products

    This product is based on CDMA network and GPS satellite positioning system, through short messages or the Internet to locate or monitor remote targets. The product is modular design. It connects the platform server through the CDMA network module, receives the satellite positioning signal through the GPS module, and MCU controls various peripherals. Professional module makes the product have very stable performance and powerful use function.


    Technical Specifications

    content

    Specifications

    size

    87mm *65mm *26mm

    Net weight

    0.51kgs

    network

    CDMA

    Network Frequency Band

    CDMA2000 1X 800Mhz

    GPS module

    GT

    GPS Sensitivity

    -165dBm

    GPS positioning accuracy

    5 meters

    Location query mode

    Mobile phones or platforms

    working voltage

    DC9V—36V

    Spare battery

    3.7V 850mAh

    Standby current

    Less than 50 mA

    Storage temperature

    -40°C to +85°C

    working temperature

    -20°C to +70°C

    Operating Humidity

    5%--95%RH


    VI. Product Accessories

    1. Power cord

    2. GPS antenna

    3. GSM antenna

    4. SIM chute

    5. Instructions


    Installation instructions

    1. Preparations before installation

    1.1 Put SIM card in the card seat.

    1.2 Insert the card holder into the locator host.




    Note: Make sure that SIM card is on call display and not on call transfer and PIN code is off. Mobile SMS must be in plain text format, and cannot recognize PDU format.


    2. Installation of positioner

    The installation of GPS/GSM/GPRS vehicle-borne vehicle needs to be handled by the professional maintenance technicians affiliated to the local service center. Without the company's permission, users are not allowed to disassemble or repair at will, otherwise the consequences are at their own expense.


    2.1 Connection Box





    2.2 Installation of GPS Locator


    Port wiring diagram












    Installation steps: (The following operations are carried out without power at the terminal, otherwise there will be danger)




















    VIII. Usage

    Setting up equipment operation mode

    A. There are two modes of operation for devices. One is administrator mode, the other is no administrator mode. In the administrator mode, only the set number can operate the device. In no administrator mode, all numbers can operate on the device. The device defaults to "no administrator status".

    The way to set the device as an administrator is to send the following short message to the device:

    Administrator 123456

    The number that sends a short message becomes the administrator number. "Administrator" is the instruction, "123456" is the device password. The device changes from an administrator state to an administrator-free state by deleting the administrator number with the administrator's mobile phone.


    B. Add Number

    In the absence of an administrator, the device is dialed with a mobile phone, and the number is recorded by the device after it is connected. In the no-administrator mode, the device can record up to four numbers, and the fifth number will automatically overwrite the first number.

    In the presence of an administrator, use the administrator number to send the following short message to the device to add other numbers.

    Add number 123456 18818585694

    "Add Number" is the instruction, "123456" is the device password, "18818585694" is the number to be added. This instruction can only be operated by an administrator number.


    C. Delete Number

    In the absence of an administrator, the device can record up to four numbers, and the fifth number will automatically overwrite the first number.

    In the presence of an administrator, use the administrator number to send the following message to the device deletion number.

    Delete number 123456 18818585694

    "Delete number" is the instruction, "123456" is the device password, "18818585694" is the number to be deleted. This instruction can only be operated by an administrator number. If the administrator deletes his own number, the device will return to the state of no administrator and automatically delete other numbers.


    D. Modifying Password

    Send the following text message to the device to change the password.

    Modified password 123456 189189

    "Modify password" is the instruction, "123456" is the old password of the device, "189189" is the new password of the device. The password must be six digits. The initial password of the device is 123456. In the administrator state, this instruction can only be operated by the administrator number. In the absence of an administrator, all numbers can be manipulated.


    E. Oil Circuit Control

    The oil circuit of the vehicle equipped with the equipment can be controlled by short message. To disconnect the fuel line of the vehicle, send the following text message to the device.

    Oil cut 123456

    "Oil cut" is the instruction and "123456" is the password. To close the oil circuit, send the following text message to the device.

    Fuel supply 123456

    "Fuel supply" is the instruction and "123456" is the password. In the state of administrator, only the number set can be operated, and in the state of no administrator, all numbers can be operated.


    F. Circuit Control

    The circuit of the vehicle installed with the equipment can be controlled by short message. To disconnect the vehicle circuit, send the following short message to the device.

    Blackout 123456

    "Power off" is the instruction and "123456" is the password. To close the circuit, send the following text message to the device.

    Power supply 123456

    "Fuel supply" is the instruction and "123456" is the password. In the state of administrator, only the number set can be operated, and in the state of no administrator, all numbers can be operated.


    G. Monitoring equipment

    You can monitor by dialing the terminal number. In the administrator state, only the number set can be monitored. In the absence of an administrator, all numbers can be monitored.


    H. Motion Alarm

    By sending the following text messages to the device, the motion alarm function is activated.

    Motion Alarm

    "Motion Alarm" is an instruction that does not require a password. After successful setting, the device will return a short message, the content is: "Setting the motion alarm successfully". When this function is activated, a text message will be sent to the mobile phone with this function when the vehicle is moving, indicating that the vehicle is already moving. "This function must be valid only when the GPS signal is available." Cancel the motion alarm function to send the following text messages to the device.

    Cancel Motion Alarm

    "Cancel Motion Alarm" is an instruction that does not require a password. In the administrator state, only the set number can operate this function. In the absence of an administrator, all numbers can operate this function.


    I. Overspeed alarm

    By sending the following text messages to the device, the speeding alarm function is activated.

    Overspeed alarm 80

    "Overspeed alarm" is an instruction and "80" is a speed limit of 80 km/h. This instruction does not require a password. After successful setup, the device will return a short message, which reads: "Set the alarm successfully for speeding". When this function is activated, when the speed of the vehicle exceeds the set speed, a short message will be sent to the mobile phone with this function, indicating that the vehicle has exceeded the speed limit. "This function must be valid only when the GPS signal is available." Cancel the overspeed alarm function to send the following text messages to the device.

    Cancel overspeed alarm

    "Cancel overspeed alarm" is an instruction that does not require a password. In the administrator state, only the set number can operate this function. In the absence of an administrator, all numbers can operate this function.


    J. The dimension of mobile phone acquisition

    The current longitude dimension of the vehicle installed with the device can be obtained by mobile phone. Send the following text message to the device.

    Mobile Location

    "Mobile Location" is an instruction that does not require a password. Whether the device is in an administrator state or in an administrator-free state, any number can send this instruction.


    K. Setting Equipment Number

    Setting platform number, using and binding platform, according to the specific platform to be effective. Set the method to send the following content to the device.

    Equipment number 18818585694

    "Equipment Number" is the instruction, and "18818585694" is the 11-digit mobile phone number, which must be 11-digit.


    L. Restart System

    Send the following content to the terminal device number through the mobile phone, and the terminal device will be restarted.

    Restart System 123456

    "Restart the system" is the instruction and "123456" is the password. After restarting the system, the equipment will return to the state of oil supply and power supply.


    M. Setting the transmission interval

    Set the interval between the data returned by the terminal device and the platform through the mobile phone. Send the following to the terminal device number.

    Location time 3 times 5

    "Location time" is the instruction, and "3" is the interval between data transmission to the platform, which means that data transmission to the platform once in 3 minutes must be less than 256 minutes. "Number" is an instruction and "5" is a transmission number, indicating that the transmission will stop after five transfers. Must be less than 256 times. Number of times "*" means an infinite number of transfers. For example, "Location time 1 times *" means that data is transmitted to the platform every minute and continuously. To cancel the transfer, you can send the following to the device number.

    Cancellation of positioning

    The device will stop transmitting data to the platform. Secondary functions can also be implemented through the platform, depending on whether the specific platform supports this function.


    N. Restore the initial password

    When the password of the device is forgotten, a short message can be sent to restore the device to its original password. Send the following text message to the device number.

    Restore the initial password

    "Restore the initial password" is the instruction. In the absence of an administrator, all numbers can operate secondary functions. In the absence of an administrator, only an administrator can operate this function. The initial password of the device is 123456.


    O, Modify IP Address and Port

    The IP address and port of the device terminal can be modified so that the device can transmit data to another platform. Send the following text message to the terminal number.

    Address 123.67.87.9 Port 344

    "Address" is the instruction, "123.67.87.9" is the IP address, "port" is the instruction, "344" is the port number.


    IX. Notes

    1. Read the instructions carefully before installing the equipment.

    2. Before installation, please insert SIM card to support the determination of CDMA network traffic card, and ensure that the SIM card opens the call display, does not open the call transfer, does not set the password, otherwise the equipment will not work properly.

    3. The working voltage of this equipment is 9V-30V. Please use it in the range of working voltage.

    4. Please confirm that all equipment and connection lines are connected correctly before connecting to the mainframe power supply. Do not install or disassemble when the host is powered on. If missing wires or misconnection are found, please cut off the power supply first, otherwise the equipment will be damaged easily.

    5. This equipment is a wireless communication equipment. Please cut off the power supply of the main engine before entering the oil depot and dangerous goods place.

    6. In order to avoid EMI or incompatible configuration, please stop using the equipment according to the regulations in places where notice is attached.

    7. Maintain the use of equipment in dry environment, humid environment is easy to damage the internal circuit.

    8. Clean it with dry cloth instead of using chemicals and detergents.


    10. After-sales Service

    Warranty Statement:

    1. If there are any technical changes in this product in the future, no further notice will be given.

    2. If the appearance and color of the product are changed, the material object shall prevail.

    3. The warranty card is only applicable to the three-package service of IMEI/ID machine listed below.

    4. Please keep this repair card properly.

    5. Please refer to the following table for details of the warranty scope.

    This card is the basic voucher of warranty. Please fill in this card carefully and keep it properly.

    User Name

    Contact number

    Product Model

    IMEI/ID No.

    Date of purchase

    Invoice number